Vue de la page 19
®
18
VEHICLE
BATTERY
Ground Stud
Power Stud
SNO-PRO / HOME-PRO / TRIP-EDGE w/HYD. JACK:
AUTOMATIC JACK RETRACT FUNCTION - ELECTRICAL
C.)
B.)
F. )
D.)
Plow Lift
Red Wire
E.)
Jack Retract
Pink/Black Wire
Ground Connection
Internal in Plow Side
Harness
Solenoid Control
Brown Wire
12vdc Switched
By Solenoid
Switch Panel Control
Viewed From Behind
A-Frame
Jack Switch
Chassis Ground
Continuous Connection
Angle Switch
Headlight Switch
Lift/Float Switch
A.)
12vdc Source
Black Wire
Must Be Ignition Switched
15a Fuse
What Happens:
A.) Ignition 'On' energizes the Controller Power source sending 12vdc into the Controller. If equipped with a Joystick or
Touch Pad, the Controller Power Switch must be in the 'On' position.
B.) Moving the Controller to 'Plow Lift' position energizes the Red 'Plow Lift' Wire, the Brown 'Solenoid' Wire, and the Pink/Black
'Jack Retract' Wire.
C.) The Brown 'Solenoid' Wire closes the Solenoid Contacts and sends 12vdc power to the Pump Motor.
D.) The Red 'Plow Lift' Wire sends 12vdc power to the Plow Lift Valve Coil.
E.) The Pink/Black 'Jack Retract' Wire sends 12vdc power to the Jack Retract Valve Coil.
F.) Note: A Diode is installed between the connection of the Red 'Plow Lift' Wire and the Pink/Black 'Jack Retract' Wire. This prevents the
Plow Lift Circuit from being activated when the A-Frame Jack Switch is used for the Jack Retract function.
G.) See Next Page for Hydraulic Flow Chart.